Failing cleaning validation within media prep due to excessive bioburden readings and visual failures. Seiberling investigated and determined the root cause, which was poor piping design, low cleaning velocities and dead-legs in the system. Several options were presented for review; ultimately, the agreed upon method was designed and implemented. Post commissioning, cleaning validation passed successfully on the first time.